BCD436HPandBCD536HPOwner’s Manual©2014 Uniden America Corporation Printed in Vietnam U01UB375ZZA(0)
2This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful inter
92Close Call Sensitivity (No Modulation)(NFM) 40.8400 MHz -60dBm(FM) 72.5150 MHz -62dBm(AM) 127.1750 MHz -67dBm(NFM) 161.9850 MHz -66dBm(AM) 272.9500
93WARRANTY INFORMATIONWARRANTOR: UNIDEN AMERICA CORPORATION (Uniden) ELEMENTS OF WARRANTY: Uniden warrants, for one year, to the original retail owner
3legal requirement that scanners be manufactured so they are not easy to modify to pick up these transmissions. Do not open your scanners case to make
4INTRODUCTIONThe Uniden BCD536HP and BCD436HP are digital TrunkTracker V communications receivers that require no user programming. Simply turn it on,
5REPLAY TRANSMISSIONS Your scanner Replay feature acts as an instant replay of the transmissions you’ve just heard. You can set how long a period Repl
6Trunking Discovery – Monitors system trafc on a trunked radio system to nd unknown IDs and automatically records audio from and logs new channels f
7100 Quick Keys – You can scan Favorites Lists and Systems by assigning them to quick keys.Search Avoids – You can temporarily Avoid up to 250 frequen
8INCLUDED WITH YOUR SCANNERAccessories included in the box are: BCD436HP BCD536HPUSB Connection Cable AC Power Adapter3 X AA NiMH Rechargeable Batteri
9BCD536HPINSTALLING YOUR SCANNERThe BCD536HP can be placed on a convenient surface in your home as a base station, and connected to a standard outlet
10WARNING! If you connect an external speaker to the scanner’s Ext. SP jack or headphone jack, never connect the audio output line to a power supply
11VEHICLE INSTALLATIONYou can mount your scanner in your vehicle, using either the supplied bracket or the optional DIN-E sleeve.If the scanner loses
The AMBE+2™ voice coding Technology embodied in this product is protected by intellectual property rights including patent rights, copyrights and trad
121. Using appropriate screws or other hardware, secure the bracket.2. Insert the scanner and insert the bracket knobs to lock the scanner in positi
135. Before inserting the scanner in the sleeve, attach the cable from the previously mounted antenna. Attach the DC Power leads. RED goes to a posit
14Mounting Using ISO TechniqueSome vehicles can take advantage of another approach to mounting a radio in a vehicle, called the ISO technique. However
15Using Rechargeable BatteriesYou can also use three rechargeable batteries to power your scanner. Before you use rechargeable batteries, you must cha
16Favorites Lists from the database as well as program new systems, departments, sites, and channels with the Sentinal software. You can save up to 25
17MANAGE FIRMWARE UPDATES For information about what is included in each update, see: • http://info.uniden.com/UnidenMan4/BCD536HP, or• http://info.
18SETTING UP YOUR SCANNERTURN ON THE SCANNERScroll ControlFuncMenuBCD436HPSquelchVolumeBCD536HPFor Model Number ProcedureBCD436HP1. Press and hold f
19KEYPAD AND KNOB CONTROLSBCD536HPKey OperationPower/VOL Light • Turns the scanner on/o and adjusts the volume.• Press Func then Vol to view P25 Ad
20Key OperationAvoid • Press to return to previous mode in Menu mode.• Press to toggle Channel/Frequency Avoid status in Receive/Hold modes.• Pres
21Key OperationScroll Control (Volume, Squelch)• Press then turn to adjust volume level in Scan mode.• Press Func then Vol turn to adjust the squelc
CONTENTSIMPORTANT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1THE FCC WANTS YOU TO KNOW .
22COMMON CONTROLS (BCD436HP and BCD536HP)System • Press Func then System to start Scan mode.• Press to enter System Pause for 2 seconds then hold on
23Number keys • Press to select Favorites Lists in Scan mode.• Press 0-9 to use direct entry in Hold mode.• Press 0-9 to toggle custom search bands
24SET YOUR LOCATION AND RANGEPress Menu then scroll to Set Your Location and press E/yes.Scroll to through the following option and press E/yes.SET LO
25information included, the range setting will have no effect on them because the scanner doesn’t know where they are.2. You will receive Departments
26NAVIGATING THE MENUSThe Menu key lets you select options to set up and use the scanner. To select a menu item, rotate the scroll control. Rotate rig
2710 sec - Turns the backlight on for 10 seconds when you press .30 sec - Turns the backlight on for 30 seconds when you press .60 sec - Turns the b
28View the Battery Level (BCD436HP Only) To view the battery level (in volts) press the scroll control and look at the small numbers in the upper righ
29Displays to show Function mode.F0-9 Indicates the first digit of the Favorites List quick key on the left with the blinking second digit on the righ
30S0-9 Display the first digit of the current System quick key on the left with the blinking second digit on the right.A non-blinking number on the ri
31ID Scanning/SearchingDisplays for a trunked system in Scan mode.Channel Name Displays in Receiving/Hold modes.Displays when receiving a priority cha
MANAGE PROFILES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16MANAGE FAVORITES LIS
32SETTINGS MENUPress Menu then scroll to Settings and press E/yes.Scroll to the options below and press E/yes.Adjust Key Beep Auto Shutoff Restore Opt
33Set Time Set Hour. Enter the Hour (0-23).Set Minute. Enter the minute.Set Time Zone Scroll to your time zone.Set Daylight Saving On or OffReplay Opt
34Access Point Mode is able to connect with up to 5 clients.Setting parameters are as follows: SSID, Security type, and Password. Wi-Fi OPTIONSMake su
35SYSTEM QUICK KEYSSystem Quick Keys are used to enable or disable conventional and trunking systems for scanning. You can assign any quick key to one
36Review/Edit System Add Current dB ChannelsSet FL Quick Key RenameSet FL Number Tag DeleteDet FL Startup Key InformationUse Location ControlReview A
37Note 4: When adding channels from a Favorites List that has Use Location Control is set to No, only channels that are from the selected service type
38Scroll to the Favorites List and press E/yes. Scroll to Review/Edit System and press E/yes.To Create a New System, scroll to New System and press E/
39SYSTEM OPTIONSPress Menu then scroll to Manage Favorites and press E/yes.Scroll to the Favorites List and press E/yes. Scroll to Review/Edit System
40Edit Fleet Map (Motorola Type I/lli systems Only) – This allows you to program a eet map for Motorola Type I Systems. You must program a system ee
41At Confirm?, press E/yes or ./no.Nothing Avoided appears if nothing is Avoided. Set Audio AGC – This allows you to turn AGC (Automatic Gain Control)
STARTUP KEYS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35NUMBER TAGS .
42Edit Name Set Modulation P25 Threshold ModeSet Site Type Set Attenuator P25 Threshold LevelEdit Band Plan Set Avoid Delete SiteSet Frequencies Set L
43Set Base FreqInput Lower. Enter the lower base frequency and press E/yes.Input Upper. Enter the upper base frequency and press E/yes.Set OffsetInput
44Latitude - Bottom RightEnter the latitude. Press ./no to toggle N or S, and press E/yes.Longitude - Bottom RightEnter the longitude. Press ./no to t
45DEPARTMENT OPTIONS Edit Name Set Location Information Delete DepartmentEdit Channel Set Avoid New DepartmentEdit Name See Data Naming.Edit Channel S
46PROGRAMMING FREQUENCIES/TGIDSQUICKLY STORING A FREQUENCY/TGIDIn scan mode press Channel to hold on any channel.Enter the Frequency or TGID and press
47Set Audio Type Set Delay Time Volume OffsetSet Number Tag Set Priority Delete ChannelSet Modulation New ChannelEdit Name See Data Naming.Edit Freque
48Set Number Tag – This allows you to number a Channel so you can access it quickly from scan hold mode. The default setting is no number tag. See als
49-3, -2, -1, 0, 1, 2, or 3Note: You can also toggle volume offset for a channel in scan hold mode by pressing Func then 0(LVL).Delete Channel – Delet
50Information – This will show the database version in the scanner.USING STARTUP KEYSTO USE A STARTUP KEY:1. Turn the scanner off.2. Press and hold
51Set Priority – Sets the Priority mode. You can also toggle these modes by holding on any channel in scan mode and pressing Func then ./no(Pri).Off -
CHANNEL VOLUME OFFSET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56AVOIDING CHANNELS, DEPARTMENTS
52Scanning Checklist:1. You must enable at least one Favorites List or the Full Database in Select Lists to Monitor.2. Favorites Lists or Systems, w
53SELECTING QUICK KEYS Select a Favorites List Quick Key – Press the number key(s) assigned to the Favorites List then press E/yes. Example: 00, E/yes
54TOGGLE ID SCAN OR ID SEARCH While scanning each Trunked System, press Func then E/yes.SELECT SERVICE TYPES (BCD536HP) Press Serv.(BCD436HP) Press Fu
55START/STOP RECORDING While scanning, press Func then Replay.Note: Resets to Off when you turn off the scanner.ADVANCED CHANNEL MENUWhile the channel
56INTERMEDIATE FREQUENCY EXCHANGEPress Channel to hold on the channel.Press Func then 7(IFX) to toggle on or off.REPEATER FREQUENCY CONVENTIONAL CHANN
57DIRECT FREQUENCY/TGID ENTRYPress Channel to hold on any Channel.Enter the Frequency/TGID and press E/yes. Press Channel to release hold.USING NUMBER
58(BCD436HP) Hold on any channel and press Func then Avoid( ).Close Call Hit See Using Close Call.PRIORITY MODES Press Func then ./no(PRI) to toggle
59Scroll to Review/Edit System and press E/yes.Scroll to the System and press E/yes.Scroll to Edit Sys Options and press E/yes.Scroll to the following
60For the BCD436HP, use the 4-pin mini plug to connect to the scanner using a NMEA compatible GPS device. The BCD536HP has a 9-pin RS232 male serial c
61Conventional DiscoveryInput Session Name - Enter the Name and press E/yes. See Data Naming.Trunking DiscoveryInput System Name - Enter the rst few
CUSTOM SEARCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67Change Direction o
62Set DelayThis sets the Delay when monitoring a site or frequencies. 0, 1, 2, 3, 4, or 5 sec.Set LoggingThis will log all hits or just new hits.All o
63REVIEW DISCOVERYIn Review Discovery mode, you can review the results of discovery mode runs, resume runs, or restart saved discovery sessions.Press
64Stop All Avoiding. See also Search Avoids.At Confirm? Press E/yes or ./no.Rvw Search AvoidScroll to Frequency and press E/yes to Stop Avoiding. Broa
65Manual. Allows you to manually set the threshold in threshold setting mode or using the P25 Threshold Level setting.Default. Sets the scanner to th
66Set AvoidStop Avoiding, Temporary Avoid, or Permanent AvoidSet Hold Time. Sets how long to search when scanning.Enter the hold time (0-255 sec.) and
67CUSTOM SEARCHAllows you to search the scanners 10 programmed frequency ranges. See also Edit Custom Search.Press Menu. Scroll to Search for... and p
68Direct Frequency EntryPress Channel to hold on any frequency. Enter the frequency and press Channel. Press Channel to release hold. Frequency Interm
69CLOSE CALLYour scanner’s Close Call feature lets you set the scanner so it detects, alerts you to, and displays the frequency of a nearby strong rad
70Set Hold Time. Sets how long to search when scanning.Enter the hold time (0-255 sec.) and press E/yes to save.Set CC Mode Selects the Close Call mod
71When the scanner detects a Close Call signal, CC Found! and Press Any Key display for the length of time set in Close Call Pause. Toggle Close Call
Program SAME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73Weather Alert Priori
72Modulation Press Func then Channel(MOD) for all bands.Intermediate Frequency ExchangePress Channel to hold on any frequency. Press Func then 7(IFX)
73Program SAME Review WX AlertsSet Delay TimeSets the number of seconds the scanner should wait after a transmission stops before moving on to the nex
74Weather ScanPress Channel to hold on any channel/frequency. Press Func then press and hold 6(WX).The scanner starts scanning the preprogrammed weath
75The scanner displays warning level as “Warning WX,” “Watch WX” or “Advisory WX” and it displays decoded Event Code.When an alert is received, press
76Scroll to Tone-Out Setup and press E/yes.Scroll to Tone-Out (0-31) and press E/yes.Note: Close Call DND/Pri and Weather Alert Priority do not operat
77Set Audio AGC This allows you to turn AGC (Automatic Gain Control) on or off for Tone-Out operations. The default setting is Off.Analog - Press E/ye
78AttenuationPress Func then 4(ATT).ModulationPress Func then Channel(MOD).Intermediate Frequency ExchangePress Func then 7(IFX) to toggle on or off.S
79DEFAULT BAND COVERAGEFrequency RangeModeStep (kHz)BandLower Upper25.0000 26.9600AM 5Petroleum Products & Broadcast Pickup26.9650 27.4050AM 5CB C
80Although TV bands are listed, the scanner cannot decode digital TV audio.SERVICE TYPESService Type DescriptionAircraftFor civilian aircraft and air
81Service Type DescriptionRacing OfficialsAvailable for use to identify ofcials’ frequencies for racing events.Racing TeamsAvailable for use to ident
1IMPORTANT INFORMATIONTHE FCC WANTS YOU TO KNOW IMPORTANT! This scanning radio has been manufactured so that it will not tune to the radio frequencies
82System Type TGID FormatMotorola Type 2 SystemsN = Decimal NumberH = Hexadecimal Numberi = I-Call IDDecimal FormatNNNNNiNNNNNHexadecimal FormatHHHHiH
83Therefore, if someone hit their emergency button and their radio was on talk group 16, all communications would switch to talk group 18.A lot of Fir
84ST Event Code Warning Watch Advisory Denition?FCW Food Contamination Warning O FoodFFA Flash Flood Watch O Flash FloodFFS Flash Flood Statement O
85ST Event Code Warning Watch Advisory Denition?SVR Severe Thunderstorm WarningO ThunderstormSVS Severe Weather Statement O Severe WXTOA Tornado Wat
8674.4Hz 103.5Hz 146.2Hz 179.9Hz 218.1Hz77.0Hz 107.2Hz 151.4Hz 183.5Hz 225.7Hz79.7Hz 110.9Hz 156.7Hz 186.2Hz 229.1Hz82.5Hz 114.8Hz 159.8Hz 189.9Hz 233
87Base Frequency(MHz)Offset(MHz)Base Frequency(MHz)Offset(MHz)147.6000 - 147.9900 -0.6 503.0000 - 505.9875 -3148.1250 -4.375 506.0000 - 508.9875 +3158
88TECHNICAL SPECIFICATIONS BCD436HPBand Coverage : 31 BandsSize: 2.8 in (W) x 1.5 in (D) x 6.3 in (H) (without antenna) 71.1 mm (W) x 36.9 mm (
89VHF High 1 Band(NFM) 138.150 MHz 0.4 μV(NFM) 161.985 MHz 0.3 μV(NFM) 173.225 MHz 0.3 μV(WFM) 197.450 MHz 0.6 uV(NFM) 216.020 MHz 0.3 uVVHF High 2 Ba
90(FM) 72.5150 MHz 47 dB(FMB) 107.100 MHz 60 dBAircraft Band(AM) 127.1750 MHz 50 dBVHF High 1 Band(NFM) 161.9850 MHz 41 dB(NFM) 173.2250 MHz 42 dB(WFM
91Scan Delay: 2 secondsAudio Output Power : 5W Max., 8 ohm LoadAntenna: 50 ohms (Impedance)Sensitivity (12dB SINAD) NominalVHF Low Band(AM) 2
Commentaires sur ces manuels